On residential buildings in England, building height and whether an outdoor area is classified as a balcony or a roof terrace affect the applicable fire requirements. What classifications do the decking and guarding need, and what evidence should the supplier provide?
This article covers the position in England.
What Do A1 and A2-s1,d0 Fire Classifications Mean?
Reaction-to-fire classes under BS EN 13501-1 describe how a material contributes to a fire:
- A1: non-combustible, the highest class;
- A2: limited combustibility;
- s1: very limited smoke production;
- d0: no flaming droplets or particles.
So A2-s1,d0 means limited combustibility, very limited smoke and no flaming droplets. That is the benchmark for balconies on taller residential buildings.
What Are the Fire Safety Rules for Decking Above 11 Metres?
18 metres and above. On “relevant buildings”, as defined in the Building Regulations, with a storey at least 18 m above ground level, Regulation 7(2) restricts the materials used in external walls and specified attachments, including balconies. Materials must achieve class A2-s1,d0 or A1, with limited exemptions such as waterproofing membranes.
11 to 18 metres. The amendments to Approved Document B that took effect on 1 December 2022 introduced guidance for balconies on residential buildings with a storey at least 11 metres above ground level. The guidance includes a route using materials classified A1 or A2-s1,d0, subject to specified exceptions, alongside an alternative balcony construction arrangement.
Roof terraces. A terrace over habitable, heated space is usually treated as a roof rather than a balcony, so its external fire performance is assessed as a roof system (typically BROOF(t4), assessed as installed). Whether a particular terrace is treated as a balcony or a roof is a question to settle with Building Control early, because it changes what the decking and guarding need to show.
How BalcoDeck® meets it?
BalcoDeck® was developed as an all-aluminium deck and glass balustrade system, so it can be used where combustible decking can’t. Its certificate of compliance classifies:
- The BalcoDeck® aluminium decking is classified A2-s1,d0.
- The specified glass balustrade assembly combines materials classified A1 and A2-s1,d0, with exceptions for certain components as permitted by the applicable rules.
The substructure is aluminium too, and it sits on the finished roof without penetrating the waterproofing. Where the project’s fire requirements permit, BalcoDeck® system can also be supplied with composite decking.

BalcoDeck® roof terrace, Hove
Case Study: Fire-Rated Roof Terrace Decking in Hove
In Hove, a developer added a storey to an existing building, creating a new apartment with its own roof terrace. At Hove, the building had a storey more than 11 metres above ground level, which triggered the project’s fire-classification requirements for the terrace materials. We supplied suitably fire-classified BalcoDeck® aluminium decking and glass balustrading on the non-penetrative aluminium substructure. That gave the apartment a usable roof terrace that met the fire requirement, without compromising the existing waterproofing or structure.
Explore more BalcoDeck® case studies to see how our decking and balustrade systems have been used on other projects.
What Fire Certification Should You Request for Roof Terrace Decking?
When specifying decking for a balcony or roof terrace on a residential building over 11 m, ask the manufacturer for the classification of each component and the test or classification reports behind it, not just a product description. For BalcoDeck®, we can provide the certificate of compliance and our combined fire classification evidence pack for your design team and Building Control.
Need Fire-Rated Decking for Your Roof Terrace?
Planning a balcony or roof terrace project? Send us the building height, building use, whether the area is a balcony or a terrace over habitable space, and any drawings or photographs.
Call 01342 410411 to discuss your project with our team.
Fact-checked by Effi Wolff, Founder of Balconette/BalcoDeck